BCSCX - LECTRA CLEAN C AEROSOL 2039
- MSDS: BCSCX
- Manufacturer: CRC CHEMICALS
- Product Name: LECTRA CLEAN C AEROSOL 2039
- National Stock Number: 6810-00N009317
Product Identification
Product ID:LECTRA CLEAN C AEROSOL 2039
MSDS Date:11/01/1985
FSC:6810
NIIN:00N009317
MSDS Number: BCSCX
Responsible Party
WARMINSTER, PA 18974
Emergency Phone: 215-674-4300
Info Phone: 215-674-4300
Preparer: A.B. REED
Cage: CRCCE
Contractor
Telephone: 215-674-4300/800-424-9300
Cage: 10136
Ingredients
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 92%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 4%
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM/30000STEL;93
1,2-BUTYLENE OXIDE (SARA III)
CAS: 106-88-7
RTECS: EK3675000
Fraction By Weight: Fraction by Wt
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
DIETHYLENE ETHER
CAS: 123-91-1
RTECS: VG8225000
Fraction By Weight: Fraction by Wt
OSHA PEL S, 100 PPM
ACGIH TLV: S, 25 PPM; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
NITROMETHANE
CAS: 75-52-5
RTECS: PA9800000
Fraction By Weight: Fraction by Wt
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM; 9192
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS & SYMPTOMS OF OVEREXPOSURE.
Explanation of Carcinogenicity:IARC:PROBABLE HUMAN CARCINOGEN(GROUP
2B).NTP:REASONABLY ANTICIPATED TO BE CARCINOGENS
Effects of Overexposure:INHAL:HEADACHE,NAUSEA,ANESTHETIC EFFECTS &
UNCONSCIOUSNESS.EYES:BURNING & IRRITATION.SKIN:DEFATTING & DRYING.
DERMITITUS-MAY HAVE SOME EFFECT ON LIVER & KIDNEYS.
Medical Cond Aggravated by Exposure:VERY HIGH CONC (78000 PPM) MAY
CAUSE CARDIAC ARRYTHYMIAS.(MFR)
First Aid
First Aid:IF SYMPTOMS PERSIST,CALL A PHYSICIAN.INHAL:REMOVE TO FRESH
AIR-APPLY ARITIFICIAL RESPIRATION IF NEEDED.EYES:FLUSH WITH WATER
FOR 15 MINUTES.SKIN:WASH WITH SOAP & H*2O.INGEST:DO NOT INDUCE
VOMITING-CAL L A PHYSICIAN.
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Lower Limits:8%
Upper Limits:10.5%
Extinguishing Media:FOAM,DRY CHEMICAL,FOG
Fire Fighting Procedures:WEAR PRESSURE DEMAND SCBA AND FULL PROTECTIVE
EQUIPMENT.
Unusual Fire/Explosion Hazard:AEROSOL PACKAGES MAY EXPLODE IF HEATED
ABOVE 130F. THERMAL DECOMP PRODUCTS MAY INCLUDE HCL & PHOSGENE
Accidental Release
Spill Release Procedures:VENT AREA-ABSORB WITH INERT MATERIAL & PUT IN
A CLOSED CONTAINER-DISPOSE AS HAZARDOUS WASTE.
Handling
Handling and Storage Precautions:STORE IN A COOL DRY AREA.
Other Precautions:AEROSOLS MAY EXPLODE IF CONTENTS HEATED TO 130F.
VAPORS ARE HEAVY & COLLLECT IN CONFINED AREAS,LOW SPOTS & PITS. NO
SMOKING IN AREA OF USE.DO NOT USE IN THE GENERAL VICINITY OF ARC
WELDING OPEN FLAMES OR HOT SURFACES. HEAT (SEE SUP DATA)
Exposure Controls
Respiratory Protection:SCBA IF VAPORS CONC.ABOVE TLV,NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
Ventilation:MAINTAIN VAPOR CONC BELOW TLV. USE MECHANICAL MEANS IF
NEEDED.
Protective Gloves:SOLVENT RESISTANT
Eye Protection:CHEMICAL WORKERS GOGGLES
Work Hygienic Practices:OBSERVE GOOD WORK HYGIENIC PRACTICES
Supplemental Safety and Health
OTHER PRECAUTIONS:AND/OR UV RADIATION MAY CAUSE THE FORMATION OF HCL
&/OR PHOSGENE
Chemical Properties
Boiling Pt:B.P. Text:165F-73.89C
Decomp Temp:Decomp Text:N/K
Vapor Pres:100 MM HG
Vapor Density:4.55
Spec Gravity:1.321
pH:
Evaporation Rate & Reference:RAPID
Solubility in Water:NEGLIGIBLE IN WATER
Appearance and Odor:WATER,WHITE LIQUID
Percent Volatiles by Volume:96
Corrosion Rate:
Stability
Stability Indicator/Materials to Avoid:YES
DO NOT STORE IN ALUMINUM
Hazardous Decomposition Products:HYDROGEN CHLORIDE CHLORINE & POSSIBLY
PHOSGENE (THERMAL).
Disposal
Waste Disposal Methods:PARTIALLY FILLED & UNUSED AEROSOLS ARE HAZARDOUS
WASTE.DISPOSE OF IN CONFORMANCE TO FEDERAL,STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.